{"id":1071,"date":"2018-07-27T14:44:31","date_gmt":"2018-07-27T14:44:31","guid":{"rendered":"https:\/\/designsacchi.com\/master26\/?p=1071"},"modified":"2021-11-20T00:45:06","modified_gmt":"2021-11-20T00:45:06","slug":"homologacao-da-anatel-para-cabos-de-telecomunicacoes","status":"publish","type":"post","link":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/","title":{"rendered":"Homologa\u00e7\u00e3o da Anatel para Cabos de Telecomunica\u00e7\u00f5es"},"content":{"rendered":"<p>[:pb]Artigo publicado em parceria com:<\/p>\n<p>Diversos tipos de cabos utilizados para o fornecimento de servi\u00e7os de telecomunica\u00e7\u00f5es devem ser homologados antes de serem autorizados para a comercializa\u00e7\u00e3o e uso no Brasil. Nesse artigo vamos listar quais os tipos de cabos de telecomunica\u00e7\u00f5es devem ser homologados no Brasil e para quais testes devem ser submetidos.<\/p>\n<h3><strong>Procedimentos de Homologa\u00e7\u00e3o para Equipamentos de Telecomunica\u00e7\u00f5es<\/strong><\/h3>\n<p>Como foi mencionado no artigo Como obter <a href=\"https:\/\/designsacchi.com\/master26\/produtos\/\" target=\"_blank\" rel=\"noopener noreferrer\">homologa\u00e7\u00e3o de produtos pela Anatel<\/a>, qualquer tipo de equipamento utilizado para telecomunica\u00e7\u00f5es precisa ser submetido a um processo de homologa\u00e7\u00e3o gerido pela Anatel antes de ser autorizado para uso e comercializa\u00e7\u00e3o no pa\u00eds. O procedimento de homologa\u00e7\u00e3o envolve m\u00faltiplos passos e inclui testes laboratoriais para assegurar a funcionalidade, resist\u00eancia e seguran\u00e7a para uso por humanos.<\/p>\n<p>Em termos gerais, todos os tipos de equipamentos que transmitem ondas de r\u00e1dio para comunica\u00e7\u00e3o de sinais precisam ser homologados, o que \u00e9 de ser esperado j\u00e1 que esses dispositivos s\u00e3o capazes de interferir com o espectro eletromagn\u00e9tico do territ\u00f3rio brasileiro e \u00e9 papel da Anatel regular quais tipos de dispositivos s\u00e3o autorizados para transmitir sinais de r\u00e1dio. Contudo, alguns tipos de equipamentos utilizados para comunica\u00e7\u00f5es por fio tamb\u00e9m precisam ser homologados, uma vez que podem ser utilizados no fornecimento de servi\u00e7os de telecomunica\u00e7\u00f5es regulados pela ag\u00eancia, como a oferta de servi\u00e7os de telefonia fixa e conex\u00f5es de banda larga.<\/p>\n<p>Cabos de telecomunica\u00e7\u00f5es se encaixam na segunda categoria de produtos que precisam ser homologados, e fabricantes e distribuidores desse tipo de equipamento devem estar cientes dos requerimentos institu\u00eddos pela Anatel para garantir que seus produtos sejam comercializados e utilizados legalmente no Brasil.<\/p>\n<h3><strong>Tipos de Cabos de Telecomunica\u00e7\u00f5es Sujeitos a Homologa\u00e7\u00e3o<\/strong><\/h3>\n<p>A Anatel institui que uma ampla variedade de cabos, desde fios de cobre utilizados para telefonia a cabos de fibra \u00f3ptica utilizados para conex\u00f5es de internet de alta velocidade, devem ser submetidos aos procedimentos de homologa\u00e7\u00e3o. Entre os tipos de cabos especificamente citados entre os equipamentos sujeitos a homologa\u00e7\u00e3o est\u00e3o:<\/p>\n<ul>\n<li>Cabos de fibra \u00f3ptica (incluindo cabos compactos e auto-sustentados)<\/li>\n<li>Cabos coaxiais (r\u00edgidos, flex\u00edveis e h\u00edbridos)<\/li>\n<li>Cabos de telefonia e de conex\u00f5es xDSL (incluindo cabos h\u00edbridos)<\/li>\n<li>Cabos de transmiss\u00e3o de dados de pares tran\u00e7ados blindados ou n\u00e3o (das categorias 3, 5e, 6 e 6A)<\/li>\n<li>Cabos de manobra com conectores RJ-45<\/li>\n<li>Fios telef\u00f4nicos de uso interno e externo<\/li>\n<\/ul>\n<p>\u00c9 importante notar que esses cabos s\u00f3 necessitam de homologa\u00e7\u00e3o no caso de serem destinados especificamente para o uso em telecomunica\u00e7\u00f5es, considerando que podem ser aplicados para fins diversos. Al\u00e9m disso, outros tipos de cabos que n\u00e3o s\u00e3o citados nos documentos de requerimentos de homologa\u00e7\u00e3o da Anatel n\u00e3o s\u00e3o necessariamente isentos de serem testados e aprovados pela Ag\u00eancia. Assim como no caso de tecnologias n\u00e3o categorizadas ou desenvolvidas recentemente, \u00e9 recomendado o envio das especifica\u00e7\u00f5es e amostras desses equipamentos para que a Anatel e ag\u00eancias credenciadas possam garantir sua conformidade com sistemas e legisla\u00e7\u00e3o nacionais.<\/p>\n<h3><strong>Requerimentos de Testes<\/strong><\/h3>\n<p>A fase dos testes laboratoriais, que \u00e9 parte do <a href=\"https:\/\/designsacchi.com\/master26\/\" target=\"_blank\" rel=\"noopener noreferrer\">procedimento de homologa\u00e7\u00e3o<\/a>, requer que par\u00e2metros e especifica\u00e7\u00f5es de cabos sejam avaliados para garantir sua funcionalidade, resist\u00eancia e seguran\u00e7a de uso. Reunimos abaixo alguns dos requerimentos de testes institu\u00eddos pela Anatel para diversos tipos de cabos de telecomunica\u00e7\u00f5es:<\/p>\n<h2><strong>Cabos de Fibra \u00d3ptica<\/strong><\/h2>\n<p>No caso de cabos de fibra \u00f3ptica, a maior parte dos testes se referem a assegurar a qualidade de fabrica\u00e7\u00e3o da fibra e sua resist\u00eancia a condi\u00e7\u00f5es adversas. Alguns desses testes incluem a medi\u00e7\u00e3o de:<\/p>\n<ul>\n<li>Comprimento da onda de corte para fibras monomodo<\/li>\n<li>Di\u00e2metro do campo modal para para fibras monomodo e multimodo<\/li>\n<li>Di\u00e2metro do n\u00facleo de fibras multimodo<\/li>\n<li>Di\u00e2metro da casca<\/li>\n<li>N\u00e3o circularidade da casca<\/li>\n<li>Concentricidade entre n\u00facleo da fibra, revestimento, campo modal e casca<\/li>\n<li>Resist\u00eancia f\u00edsica do revestimento da fibra<\/li>\n<li>Dispers\u00e3o crom\u00e1tica<\/li>\n<li>Dispers\u00e3o do modo de polariza\u00e7\u00e3o<\/li>\n<li>Resist\u00eancia t\u00e9rmica e qu\u00edmica<\/li>\n<\/ul>\n<p>Os testes de resist\u00eancia f\u00edsica podem ter requerimentos diferentes dependendo do prop\u00f3sito de cada cabo de fibra \u00f3ptica, que pode ser o uso em instala\u00e7\u00f5es internas, externas, em dutos ou em condi\u00e7\u00f5es expostas. De modo geral, os requerimentos para equipamentos destinados a instala\u00e7\u00f5es externas s\u00e3o mais rigorosos, como no caso dos testes de resist\u00eancia para ciclos t\u00e9rmicos.<br \/>\nPor exemplo, cabos de fibra \u00f3ptica desenvolvidos para instala\u00e7\u00f5es em dutos, terminais ou subterr\u00e2neas devem ser submetidos a quatro ciclos nos quais sua temperatura \u00e9 reduzida a -20\u00baC por 48 horas e subsequentemente elevada a 65\u00baC por 48 horas, durante os quais o coeficiente de atenua\u00e7\u00e3o n\u00e3o pode apresentar uma varia\u00e7\u00e3o significativa do que \u00e9 medido na temperatura de 25\u00baC. Cabos de fibra \u00f3ptica utilizados em instala\u00e7\u00f5es internas devem ser submetidos a um teste similar, por\u00e9m com varia\u00e7\u00f5es menores de temperatura, nos quais os ciclos t\u00e9rmicos variam entre 10\u00baC e 40\u00baC.<\/p>\n<p>Outros testes que verificam as qualidades f\u00edsicas dos cabos de fibra \u00f3ptica incluem a avalia\u00e7\u00e3o da resist\u00eancia a:<\/p>\n<ul>\n<li>Tra\u00e7\u00e3o<\/li>\n<li>Compress\u00e3o<\/li>\n<li>Impactos<\/li>\n<li>Tor\u00e7\u00e3o de 180\u00ba<\/li>\n<li>Tens\u00e3o de curvatura<\/li>\n<li>Flex\u00e3o<\/li>\n<li>Vibra\u00e7\u00f5es<\/li>\n<li>Umidade<\/li>\n<li>Adversidades clim\u00e1ticas<\/li>\n<li>Chamas<\/li>\n<li>Oxida\u00e7\u00e3o induzida<\/li>\n<li>Cabos Coaxiais<\/li>\n<\/ul>\n<p>A categoria de cabos coaxiais, incluindo cabos r\u00edgidos, flex\u00edveis e semi-r\u00edgidos tamb\u00e9m devem ser submetidos a testes laboratoriais para verificar sua funcionalidade e qualidade de fabrica\u00e7\u00e3o. O revestimento desses cabos, por exemplo, deve ser testado especificamente para a medi\u00e7\u00e3o de sua densidade e verifica\u00e7\u00e3o da resist\u00eancia a tra\u00e7\u00e3o, alongamento e baixas temperaturas. Outros testes de avalia\u00e7\u00e3o de resist\u00eancia e qualidade de fabrica\u00e7\u00e3o incluem a medi\u00e7\u00e3o de:<\/p>\n<ul>\n<li>Uniformidade da curvatura<\/li>\n<li>Dist\u00e2ncia entre condutor interno e externo (espec\u00edfica para cada tipo de cabo)<\/li>\n<li>Resist\u00eancia a enrolamento e dobramento<\/li>\n<li>Imped\u00e2ncia<\/li>\n<li>Perda de sinal<\/li>\n<li>Resist\u00eancia a corros\u00e3o e oxida\u00e7\u00e3o induzida<\/li>\n<li>Estabilidade t\u00e9rmica<\/li>\n<li>Fios Telef\u00f4nicos e Cabos de Conex\u00f5es xDSL<\/li>\n<\/ul>\n<p>No caso de cabos de telefonia, incluindo aqueles usados para conex\u00f5es xDSL, alguns dos testes necess\u00e1rios incluem a medi\u00e7\u00e3o de:<\/p>\n<ul>\n<li>Resist\u00eancia el\u00e9trica do condutor<br \/>\nDesequil\u00edbrio resistivo<\/li>\n<li>Desequil\u00edbrio capacitivo entre cada par e entre um par e a terra<\/li>\n<li>Resist\u00eancia el\u00e9trica do material de isolamento<\/li>\n<li>Resist\u00eancia a altas voltagens, alongamento, tra\u00e7\u00e3o e adversidades clim\u00e1ticas<\/li>\n<li>Atenua\u00e7\u00e3o de sinal por 100 metros<\/li>\n<\/ul>\n<p>Fios telef\u00f4nicos met\u00e1licos, por outro lado, devem ser testados em quesitos que incluem:<\/p>\n<ul>\n<li>Resist\u00eancia el\u00e9trica m\u00e1xima dependendo de seu di\u00e2metro e material de fabrica\u00e7\u00e3o<\/li>\n<li>Desequil\u00edbrio capacitivo entre cada par e um par e a terra<\/li>\n<li>Resist\u00eancia el\u00e9trica do material de isolamento<\/li>\n<li>Atenua\u00e7\u00e3o de sinal por 1000 metros, baseado no di\u00e2metro do cabo<\/li>\n<li>Retardamento de chamas<\/li>\n<li>Resist\u00eancia a alongamento e tra\u00e7\u00e3o<\/li>\n<li>Cabos de Par Tran\u00e7ado e Cabos de Manobra<\/li>\n<\/ul>\n<p>Os requerimentos de testes para cabos de fibras tran\u00e7adas das categorias 3, 5e, 6 e 6A s\u00e3o em sua maioria baseados em padr\u00f5es regulat\u00f3rios institu\u00eddos por organiza\u00e7\u00f5es como o American National Standards Institute e a Associa\u00e7\u00e3o Brasileira de Normas T\u00e9cninas. Alguns dos par\u00e2metros avaliados nesses testes incluem:<\/p>\n<ul>\n<li>Mapeamento de fios<\/li>\n<li>Perda de sinal de retorno<\/li>\n<li>Interfer\u00eancia cruzada entre cada par<\/li>\n<li>Di\u00e2metro do condutor<\/li>\n<li>Resist\u00eancia a tra\u00e7\u00e3o e alongamento<\/li>\n<li>Raio de dobramento<\/li>\n<li>Resist\u00eancia el\u00e9trica e desequil\u00edbrio de resist\u00eancia<\/li>\n<li>Atenua\u00e7\u00e3o de sinal em diferentes temperaturas<\/li>\n<li>Atraso de transmiss\u00e3o<\/li>\n<li>Absor\u00e7\u00e3o de radia\u00e7\u00e3o ultravioleta<\/li>\n<\/ul>\n<p>Cabos de manobra com conectores RJ-45 devem ser submetidos a testes similares, que s\u00e3o relacionados ao mapeamento de fios, interfer\u00eancia cruzada, perda de sinal de retorno e resist\u00eancia a tens\u00f5es mec\u00e2nicas.[:]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[:pb]Artigo publicado em parceria com: Diversos tipos de cabos utilizados para o fornecimento de servi\u00e7os de telecomunica\u00e7\u00f5es devem ser homologados antes de serem autorizados para a comercializa\u00e7\u00e3o e uso no Brasil. Nesse artigo vamos listar quais os tipos de cabos de telecomunica\u00e7\u00f5es devem ser homologados no Brasil e para quais testes devem ser submetidos. Procedimentos [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1075,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1071","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-noticias"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Homologa\u00e7\u00e3o da Anatel para Cabos de Telecomunica\u00e7\u00f5es - Master Certifications<\/title>\n<meta name=\"description\" content=\"Artigo publicado em parceria com: Diversos tipos de cabos utilizados para o fornecimento de servi\u00e7os de telecomunica\u00e7\u00f5es devem ser homologados antes de\" \/>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Homologa\u00e7\u00e3o da Anatel para Cabos de Telecomunica\u00e7\u00f5es - Master Certifications\" \/>\n<meta property=\"og:description\" content=\"Artigo publicado em parceria com: Diversos tipos de cabos utilizados para o fornecimento de servi\u00e7os de telecomunica\u00e7\u00f5es devem ser homologados antes de\" \/>\n<meta property=\"og:url\" content=\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/\" \/>\n<meta property=\"og:site_name\" content=\"Master Certifications\" \/>\n<meta property=\"article:published_time\" content=\"2018-07-27T14:44:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-20T00:45:06+00:00\" \/>\n<meta name=\"author\" content=\"Master Certifica\u00e7\u00f5es\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Master Certifica\u00e7\u00f5es\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/\"},\"author\":{\"name\":\"Master Certifica\u00e7\u00f5es\",\"@id\":\"https:\/\/designsacchi.com\/master26\/#\/schema\/person\/3f8357a25e002f0ec7e70fc5ea1d91b8\"},\"headline\":\"Homologa\u00e7\u00e3o da Anatel para Cabos de Telecomunica\u00e7\u00f5es\",\"datePublished\":\"2018-07-27T14:44:31+00:00\",\"dateModified\":\"2021-11-20T00:45:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/\"},\"wordCount\":1345,\"publisher\":{\"@id\":\"https:\/\/designsacchi.com\/master26\/#organization\"},\"image\":{\"@id\":\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#primaryimage\"},\"thumbnailUrl\":\"\",\"articleSection\":[\"Not\u00edcias\"],\"inLanguage\":\"pt-BR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/\",\"url\":\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/\",\"name\":\"Homologa\u00e7\u00e3o da Anatel para Cabos de Telecomunica\u00e7\u00f5es - Master Certifications\",\"isPartOf\":{\"@id\":\"https:\/\/designsacchi.com\/master26\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#primaryimage\"},\"thumbnailUrl\":\"\",\"datePublished\":\"2018-07-27T14:44:31+00:00\",\"dateModified\":\"2021-11-20T00:45:06+00:00\",\"description\":\"Artigo publicado em parceria com: Diversos tipos de cabos utilizados para o fornecimento de servi\u00e7os de telecomunica\u00e7\u00f5es devem ser homologados antes de\",\"breadcrumb\":{\"@id\":\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#primaryimage\",\"url\":\"\",\"contentUrl\":\"\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/designsacchi.com\/master26\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Not\u00edcias\",\"item\":\"https:\/\/designsacchi.com\/master26\/.\/noticias\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Homologa\u00e7\u00e3o da Anatel para Cabos de Telecomunica\u00e7\u00f5es\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/designsacchi.com\/master26\/#website\",\"url\":\"https:\/\/designsacchi.com\/master26\/\",\"name\":\"Master Certifications\",\"description\":\"Master Certifications\",\"publisher\":{\"@id\":\"https:\/\/designsacchi.com\/master26\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/designsacchi.com\/master26\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/designsacchi.com\/master26\/#organization\",\"name\":\"Master Certifica\u00e7\u00f5es\",\"url\":\"https:\/\/designsacchi.com\/master26\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/designsacchi.com\/master26\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/designsacchi.com\/master26\/wp-content\/uploads\/2019\/10\/Ativo-15.png\",\"contentUrl\":\"https:\/\/designsacchi.com\/master26\/wp-content\/uploads\/2019\/10\/Ativo-15.png\",\"width\":469,\"height\":568,\"caption\":\"Master Certifica\u00e7\u00f5es\"},\"image\":{\"@id\":\"https:\/\/designsacchi.com\/master26\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/designsacchi.com\/master26\/#\/schema\/person\/3f8357a25e002f0ec7e70fc5ea1d91b8\",\"name\":\"Master Certifica\u00e7\u00f5es\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/designsacchi.com\/master26\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/9fbf4f2726bed554477b3010e715d5416d4c2bf2ebac5708454578f9c6b191e2?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/9fbf4f2726bed554477b3010e715d5416d4c2bf2ebac5708454578f9c6b191e2?s=96&d=mm&r=g\",\"caption\":\"Master Certifica\u00e7\u00f5es\"},\"url\":\"https:\/\/designsacchi.com\/master26\/author\/alexsacchi\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Homologa\u00e7\u00e3o da Anatel para Cabos de Telecomunica\u00e7\u00f5es - Master Certifications","description":"Artigo publicado em parceria com: Diversos tipos de cabos utilizados para o fornecimento de servi\u00e7os de telecomunica\u00e7\u00f5es devem ser homologados antes de","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"pt_BR","og_type":"article","og_title":"Homologa\u00e7\u00e3o da Anatel para Cabos de Telecomunica\u00e7\u00f5es - Master Certifications","og_description":"Artigo publicado em parceria com: Diversos tipos de cabos utilizados para o fornecimento de servi\u00e7os de telecomunica\u00e7\u00f5es devem ser homologados antes de","og_url":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/","og_site_name":"Master Certifications","article_published_time":"2018-07-27T14:44:31+00:00","article_modified_time":"2021-11-20T00:45:06+00:00","author":"Master Certifica\u00e7\u00f5es","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Master Certifica\u00e7\u00f5es","Est. tempo de leitura":"6 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#article","isPartOf":{"@id":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/"},"author":{"name":"Master Certifica\u00e7\u00f5es","@id":"https:\/\/designsacchi.com\/master26\/#\/schema\/person\/3f8357a25e002f0ec7e70fc5ea1d91b8"},"headline":"Homologa\u00e7\u00e3o da Anatel para Cabos de Telecomunica\u00e7\u00f5es","datePublished":"2018-07-27T14:44:31+00:00","dateModified":"2021-11-20T00:45:06+00:00","mainEntityOfPage":{"@id":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/"},"wordCount":1345,"publisher":{"@id":"https:\/\/designsacchi.com\/master26\/#organization"},"image":{"@id":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#primaryimage"},"thumbnailUrl":"","articleSection":["Not\u00edcias"],"inLanguage":"pt-BR"},{"@type":"WebPage","@id":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/","url":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/","name":"Homologa\u00e7\u00e3o da Anatel para Cabos de Telecomunica\u00e7\u00f5es - Master Certifications","isPartOf":{"@id":"https:\/\/designsacchi.com\/master26\/#website"},"primaryImageOfPage":{"@id":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#primaryimage"},"image":{"@id":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#primaryimage"},"thumbnailUrl":"","datePublished":"2018-07-27T14:44:31+00:00","dateModified":"2021-11-20T00:45:06+00:00","description":"Artigo publicado em parceria com: Diversos tipos de cabos utilizados para o fornecimento de servi\u00e7os de telecomunica\u00e7\u00f5es devem ser homologados antes de","breadcrumb":{"@id":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#primaryimage","url":"","contentUrl":""},{"@type":"BreadcrumbList","@id":"https:\/\/designsacchi.com\/master26\/homologacao-da-anatel-para-cabos-de-telecomunicacoes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/designsacchi.com\/master26\/"},{"@type":"ListItem","position":2,"name":"Not\u00edcias","item":"https:\/\/designsacchi.com\/master26\/.\/noticias\/"},{"@type":"ListItem","position":3,"name":"Homologa\u00e7\u00e3o da Anatel para Cabos de Telecomunica\u00e7\u00f5es"}]},{"@type":"WebSite","@id":"https:\/\/designsacchi.com\/master26\/#website","url":"https:\/\/designsacchi.com\/master26\/","name":"Master Certifications","description":"Master Certifications","publisher":{"@id":"https:\/\/designsacchi.com\/master26\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/designsacchi.com\/master26\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Organization","@id":"https:\/\/designsacchi.com\/master26\/#organization","name":"Master Certifica\u00e7\u00f5es","url":"https:\/\/designsacchi.com\/master26\/","logo":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/designsacchi.com\/master26\/#\/schema\/logo\/image\/","url":"https:\/\/designsacchi.com\/master26\/wp-content\/uploads\/2019\/10\/Ativo-15.png","contentUrl":"https:\/\/designsacchi.com\/master26\/wp-content\/uploads\/2019\/10\/Ativo-15.png","width":469,"height":568,"caption":"Master Certifica\u00e7\u00f5es"},"image":{"@id":"https:\/\/designsacchi.com\/master26\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/designsacchi.com\/master26\/#\/schema\/person\/3f8357a25e002f0ec7e70fc5ea1d91b8","name":"Master Certifica\u00e7\u00f5es","image":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/designsacchi.com\/master26\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/9fbf4f2726bed554477b3010e715d5416d4c2bf2ebac5708454578f9c6b191e2?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9fbf4f2726bed554477b3010e715d5416d4c2bf2ebac5708454578f9c6b191e2?s=96&d=mm&r=g","caption":"Master Certifica\u00e7\u00f5es"},"url":"https:\/\/designsacchi.com\/master26\/author\/alexsacchi\/"}]}},"lang":"pt","translations":{"pt":1071,"en":3996},"pll_sync_post":{},"_links":{"self":[{"href":"https:\/\/designsacchi.com\/master26\/wp-json\/wp\/v2\/posts\/1071","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/designsacchi.com\/master26\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/designsacchi.com\/master26\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/designsacchi.com\/master26\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/designsacchi.com\/master26\/wp-json\/wp\/v2\/comments?post=1071"}],"version-history":[{"count":0,"href":"https:\/\/designsacchi.com\/master26\/wp-json\/wp\/v2\/posts\/1071\/revisions"}],"wp:attachment":[{"href":"https:\/\/designsacchi.com\/master26\/wp-json\/wp\/v2\/media?parent=1071"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/designsacchi.com\/master26\/wp-json\/wp\/v2\/categories?post=1071"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/designsacchi.com\/master26\/wp-json\/wp\/v2\/tags?post=1071"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}